Modelo
|
RG-S2910-24GT4XS-E
|
RG-S2910-48GT4XS-E
|
RG-S2910-10GT2SFP-P-E
|
RG-S2910C-24GT2XS-P-E
|
RG-S2910C-24GT2XS-HP-E
|
RG-S2910C-48GT2XS-HP-E
|
Puertos
|
24 10/100/1000BASE-T ports
4 1G/10GBASE-X SFP+ ports (non-combo)
|
48 10/100/1000BASE-T ports
4 1G/10GBASE-X SFP+ ports (non-combo)
|
10 10/100/1000BASE-T ports
2 100/1000BASE-X SFP ports (non-combo)
|
24 10/100/1000BASE-T ports (PoE/PoE+)
2 100/1000BASE-X SFP ports (combo)
2 1G/10GBASE-X SFP+ ports (non-combo)
|
24 10/100/1000BASE-T ports (PoE/PoE+)
2 100/1000BASE-X SFP ports (combo)
2 1G/10GBASE-X SFP+ ports (non-combo)
|
48 10/100/1000BASE-T ports (PoE/PoE+)
2 100/1000BASE-X SFP ports (combo)
2 1G/10GBASE-X SFP+ ports (non-combo)
|
Ranuras de expansion
|
N/A
|
N/A
|
N/A
|
1
|
2
|
2
|
Ranuras de alimentación modular
|
N/A
|
N/A
|
N/A
|
N/A
|
2
|
2
|
Fan Slots
|
Fixed
|
Fixed
|
Fanless
|
Fixed
|
Fixed
|
Fixed
|
Expansión Modules
|
N/A
|
N/A
|
N/A
|
M2910-01XS
M2910-01XT
M2910-02XS
M2910-04XS
M2910-02XT
|
M2910-01XS
M2910-01XT
M2910-04XS
|
M2910-01XS
M2910-01XT
M2910-04XS
|
Puertos de gestion
|
1 console port
|
1 console port
|
1 console port
|
1 console port
|
1 console port
1 USB 2.0 port
|
1 console port
1 USB 2.0 port
|
Capacidad de conmutación
|
264Gbps
|
264Gbps
|
256Gbps
|
264Gbps
|
264Gbps
|
264Gbps
|
Tasa de reenvÃo de paquetes
|
96Mpps
|
132Mpps
|
18Mpps
|
96Mpps
|
96Mpps
|
132Mpps
|
Numero de puertos 10GB
|
4
|
4
|
N/A
|
4
|
4
|
4
|
PoE
|
N/A
|
N/A
|
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking
|
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking
|
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking
|
IEEE802.3af and 802.3at power supply standards; Automatic/energy-saving (default) power supply mode; Hot startup and uninterrupted power supply; Port priority; PoE devices support stacking
|
Puerto Buffer
|
1.5MB
|
RAM
|
512MB
|
Tabla ARP
|
1,000
|
1,000
|
500
|
1,000
|
1,000
|
1,000
|
MAC Address
|
16K
|
Tamaño de tabla de rutas
(IPv4/IPv6)
|
500 (IPv4/IPv6)
|
500 (IPv4/IPv6)
|
64 (IPv4/IPv6)
|
500 (IPv4/IPv6)
|
500 (IPv4/IPv6)
|
500 (IPv4/IPv6)
|
Entradas ACL
|
In: 1,500
Out: 500
|
In: 1,500
Out: 500
|
In: 750
Out: N/A
|
In: 1,500
Out: 500
|
In: 1,500
Out: 500
|
In: 1,500
Out: 500
|
VLAN
|
4K 802.1q VLANs, Port-based VLAN, MAC-based VLAN, Protocol-based VLAN, Private VLAN, Voice VLAN, QinQ, IP subnet-based VLAN, GVRP, Guest VLAN
|
QinQ
|
Basic QinQ, Flexible QinQ, 1:1 VLAN switching, N:1 VLAN switching, 1:N VLAN switching
|
Link Agg
|
AP, LACP (maximum 8 ports can be aggregated), Cross devices AP, Flow balance
|
Duplicación de puertos
|
Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN
# RG-S2910-10GT2SFP-P-E supports N:1/1:N port mirroring, Flow-based mirroring
|
Protocolos Spanning Tree
|
IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, ROOT guard,Spanning Tree Root Guard(STRG)
|
DHCP
|
DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP snooping, IPv6 DHCP client, IPv6 DHCP relay,DHCP Snooping Option 82
|
Protocolo Multiple Instancias Spanning Tree (MSTP)
|
64
|
Max puertos de agg. (AP)
|
128
|
SDN
|
OpenFlow 1.0 & 1.3
|
VSU (Virtual Switch Unit)
|
Support (up to 9 stack members,to ensure the effectiveness of the use, 4 members are recommended* ), Local and distant stacking, Cross-chassis link aggregation in the stack, Stacking via 10G Ethernet ports
# All models support the features above except RG-S2910-10GT2SFP-P-E
|
SCN (Simplicity Campus Network)
|
Support establishing large L2 network with core devices and achieve resources pooling via VSU and VSD. Only management on core devices is required and hence simplifies horizontal and vertical network management and maintenance.
# All models support the features above except RG-S2910-10GT2SFP-P-E
|
Zero Configuración
|
CWMP(TR069)
|
L2 Caracteristicas
|
MAC, EEE, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast/Multicast/Unknown unicast storm control, IGMP v1/v2/v3 snooping, IPv6 MLD Snooping v1/v2,IGMP SGVL/IVGL, IGMP querier, IGMP filter, IGMP fast leave, DHCP, Jumbo frame, RLDP, LLDP, LLDP-MED, REUP, G.8032 ERPS, Layer 2 protocol tunnel
|
Capa 2 Protocolos
|
IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1x, IEEE802.3ab, IEEE802.1Q (GVRP), IEEE802.1D, IEEE802.1w, IEEE802.1s
|
IPv4 Caracteristicas
|
Ping, Traceroute
|
IPv6 Caracteristicas
|
ICMPv6, IPv6 Ping, IPv6 Tracert, Manually configure local address, Automatically create local address
|
IPv4 Protocol0s
|
Static Routing, RIP, OSPF v1/v2
|
Basic IPv6 Protocolos
|
IPv6 addressing, Neighbor Discovery (ND), ICMPv6, IPv6 Ping and IPv6 Tracert
|
IPv6 Protocolos
|
Static routing, RIPng, OSPF v3
|
Multicast
|
IGMP v1/v2/v3, IGMP v1/v2/v3 snooping, IGMP proxy, IGMP filter, IGMP fast leave, Multicast routing protocols (PIM-DM, PIM-SM, PIM-SSM), MLD snooping, MLD, PIM-SMv6, Multicast static routing
|
G.8032
|
Support
|
ACL
|
Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL, ACL logging, ACL counter, ACL remark, Global ACL, ACL redirect, Time-based ACL,Router ACL, VLAN ACL, Port-Based ACL
|
QoS
|
802.1p/DSCP/TOS traffic classification; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WFQ, SP+WRR, SP+DRR; Input / output port-based speed limit; Port-based traffic recognition; Each port supports 8 queue priorities; flow-based rate limiting with the minimum granularity of 8Kbps,Dynamic QoS
|
Fiabilildad
|
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)
|
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)
|
RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)
|
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol)
|
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module
|
VSU (virtualization technology for virtualizing multiple devices into 1); RIP GR; ERPS (G.8032); REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; Hot-swappable power module
|
EEE Formato
|
Support IEEE 802.3az standard
|
Seguridad
|
Binding of the IP address, MAC address, and port address; Binding of the IPv6, MAC address, and port address; Filter illegal MAC addresses; Port-based and MAC-based 802.1x; MAB; Portal and Portal 2.0 authentication; ARP-check; DAI; Restriction on the rate of ARP packets; Gateway anti-ARP spoofing; Broadcast suppression; Hierarchical management by administrators and password protection; RADIUS and TACACS+;Change of Authorization; AAA security authentication (IPv4/IPv6) in device login management; SSH and SSH V2.0; BPDU guard; IP source guard; CPP, NFPP; Port protection, CoA(RADIUS change of authorization),SCP (Secure Copy)Dynamic ARP Inspection(DAI)
|
Adminsitración
|
SNMPv1/v2c/v3, CLI (Telnet / Console), RMON (1, 2, 3, 9), SSH, Syslog / Debug, NTP / SNTP, FTP, TFTP, Web, SFLOW,HTTP or HTTPS
# RG-S2910-10GT2SFP-P-E supports SNMPv2c, CLI (Telnet / Console), Syslog, RMON (1, 2, 3, 9), Web
|
Hot Patch
|
Support
|
Control de temperatura inteligente
|
Auto fan speed adjustment; Fan malfunction alerts; Fan status check
# All models support the features above except RG-S2910-10GT2SFP-P-E
|
Alimentacion electrica inteligente
|
N/A
|
N/A
|
N/A
|
Support power control and management
|
Support power control and management
|
Support power control and management
|
Otros protocolos
|
FTP, TFTP, DNS client, DNS static
|
Dimensiones
(W x D x H)Â (mm)
|
440 × 260 × 43.6
|
440 × 260 × 43.6
|
340 × 260 × 44
|
440 × 260 × 44
|
440 × 320 × 44
|
440 × 360 × 44
|
Rack Height
|
1RU
|
|
Peso
|
≤3.5kg
|
≤4kg
|
<2.5kg
|
5.8kg (gross weight)
|
5.8kg (gross weight)
|
6.8kg (gross weight)
|
MTBF (Horas)
|
614844
|
511280
|
590278
|
361726
|
501032
|
451363
|
Protección contra rayos
|
4KV |
4KV |
6KV |
6KV
|
6KV
|
6KV
|
Fuente de poder
|
AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 1.5A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 0.5A to 0.1A |
AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 1.5A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 0.8A to 0.5A |
AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 2A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 1.0A to 0.4A
|
AC input:
Rated voltage range: 100V to 240V AC
Maximum voltage range: 90V to 264V AC
Frequency: 50/60Hz
Rated current: 6A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 3.5A to 2.5A |
AC power (RG-M5000E-AC500P):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current range: 7A to 3.5A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 3.5A to 2.5A
DC power (RG-M5000E-DC500P):
Rated voltage range: -36V to -72V DC
Rated current: 16.5A
AC power (RG-RG-PA1150P-F):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current: 10A
HVDC input:
Input voltage range: 192V to 290V DC
Rated current range: 10A |
AC power (RG-M5000E-AC500P):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current range: 7A to 3.5A
HVDC input:
Input voltage range: 192V to 290V DC
Input current range: 3.5A to 2.5A
DC power (RG-M5000E-DC500P):
Rated voltage range: -36V to -72V DC
Rated current: 16.5A
AC power (RG-RG-PA1150P-F):
Rated voltage range: 100V to 240V AC
Frequency: 50/60Hz
Rated current: 10A
HVDC input:
Input voltage range: 192V to 290V DC
Rated current range: 10A |
Consumo de energia
|
24W
|
50W
|
165W (with 8-port PoE or 4-port PoE+)
|
470W (with full PoE)
|
850W (with 24-port PoE+)
|
1700W (with 48-port PoE+)
|
PoE
|
N/A
|
N/A
|
125W
|
370W
|
RG-M5000E-AC500P: 370W
RG-M5000E-DC500P: 370W
RG-PA1150P-F: 740W
|
RG-M5000E-AC500P: 370W
RG-M5000E-DC500P: 370W
RG-PA1150P-F: 740W
|
Temperatura
|
Operating temperature: 0°C to 50°C
|
Operating temperature: 0°C to 50°C
|
Operating temperature: 0°C to 45°C
|
Operating temperature: 0°C to 50°C
|
Operating temperature: 0°C to 50°C
|
Operating temperature: 0°C to 50°C
|
Storage temperature: -40°C to 70°C
|
Humedad
|
Operating humidity: 10% to 90%RH
|
Storage humidity: 5% to 95%RH
|
Altitud de operatividad
|
-500m to 5,000m
|
Reviews
There are no reviews yet.